NTP 139 — Install an I-011G-P indoor ONT
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 139-3
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Figure NTP 139-1: I-011G-P indoor ONT connections
6 Connect the Ethernet cable to the RJ-45 port (DLP 101).
7 Connect the coaxial cable to the F-Type connector (DLP 116).
8 Connect the fiber optic cable to the ONT with the SC/APC connector. (DLP 125).
9 Connect the power cable with an AC/DC power adapter to the ONT unit power
connector as shown in Figure NTP 139-1.
10 If used, configure the SLID (DLP 129).
11 Verify the ONT LEDs, voltage status, and optical signal levels (DLP 127).
12 Activate and test the services (DLP 128).
13 If necessary, reset the ONT (DLP 126.)
14 STOP. This procedure is complete.
Warning — Be careful to maintain a bend radius of no less than 1.18
inches (3.0 cm) when connecting the fiber optic cable. A bend radius in
the cable that is too small can damage the optic fiber.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.