7 — EPON ONT overview
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 7-19
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Table 7-4 RSSI thresholds for supported SFPs / XFPs per board type
Alarms
ISAM supports configurable high and low threshold values for certain ONT alarm
conditions at a specific PON interface or ONT interface on the PON. An alarm is
raised if the condition exceeds the specified threshold value in a time period. Not all
alarm conditions have TCA support.
Table 7-5 identifies TCA-supported ONT alarm conditions by interface location.
Locations include:
PON interface
ONT interface
Table 7-5 TCA-supported ONT alarm conditions
Board Type Mnemonic Supported SFPs/XFPs Limit of Thresholds per
RSSI Profile
8-port EPON LT FPLT-A EPON PX20+
EPON PX20+ OTDR
20
4-port 10G EPON LT FPXT-A PRX30 /PR30 XFP 32
NT / NTIO FANT-F
FNIO-B
GE-BX10-D
1000Base-T
10GE-R
1000Base - PX20-U
28
Alarm Description
PON interface
RXPWLO Receive optical signal too low alarm
RXPWHI Receive optical signal too high alarm
TXPWHIALM Transmit optical power too high
TXPWLOALM Transmit optical power too low
TXBIASHIALM Transmit bias too high
TXBIASLOALM Transmit bias too low
VOLHIALM Voltage too high
VOLLOALM Voltage too low
TEMPEHIALM Temperature too high
TEMPLOALM Temperature too low
TXPWHIWARN Transmit optical power too high
TXBIASHIWARN Transmit bias too high
TXBIASLOWARN Transmit bias too low
VOLHIWARN Voltage too high
(1 of 2)