28 — I-211M-K and I-211M-L unit data sheet
28-10 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
28.7 I-211M-K and I-211M-L GEM ports and T-CONTs
Table 28-11 lists the maximum number of supported T-CONTs and GEM ports for
I-211M-K and I-211M-L indoor ONTs. Not all ONTs will be supported in all of the
releases indicated the table. See the appropriate release Customer Release Notes for
the most accurate list of supported devices.
Table 28-11 I-211M-K and I-211M-L indoor ONTs capacity for GEM ports and T-CONTs per package and
release
28.8 I-211M-K and I-211M-L power support
For the I-211M-K and I-211M-L ONT, contact your Alcatel-Lucent technical
support representative for more information.
Indoor MoCA ONT (I-211M-L within an outdoor enclosure)
wall mounted Operating for the I-211M-L ONT when wall mounted
inside a temperature-hardened outdoor enclosure:
–40°F to 149°F (–40° to 65°C) without solar loading
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
Storage:
32°F to 104°F (0°C to 40°C)
5% to 95% relative humidity, non-condensing
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
Indoor MoCA ONTs (I-211M-L within a Just Inside enclosure)
Wall mounted or
in-wall in a
preconstructed
telecommunications
cabinet
Operating:
-4°F to 122°F (-20°C to 50°C)
5% to 95% relative humidity, non-condensing
Maximum operating altitude is 10 000
ft (3048 m) above mean sea level
Storage:
–4°F to 122°F (–20°C to 50°C)
Maximum non-operating altitude is
40 000 ft (12 192 m) above mean sea
level
ONT type
Mounting method Temperature range and humidity Altitude
(2 of 2)
ONT or MDU Release Maximum Notes
Package B ONTs
GEM ports per indoor
or outdoor ONT
All 30 32 are present: 30 are available, 2
are reserved for multicast and
debugging
T-CONTs per indoor or
outdoor ONT
All 31 32 are present: 31 are available, 1
is reserved for OMCI

Table of Contents