NTP 101 — Replace a B-0404-A
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 101-3
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Figure NTP 101-1: B-0404-A connections
3 Replace the old unit with a new unit.
4 Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
5 Connect the E1/T1 cable assembly to the RJ-48C ports (DLP 104).
6 If the B-0404-A business ONT is powered using:
a a power converter, go to step 7.
b a UPS, go to step 8.
7 Install the power converter.
i Connect the ac power cable to the power converter (1AF 01226 AK), and plug
the power converter into the electric outlet as shown in Figure NTP 101-2.
Note — Observe the following:
The power converter must be located within 5 ft (1.5 m) of the
device.
The power converter must be located within 6 ft (1.8 m) of an
electrical outlet.
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.
1
2 3
4
PON
LINE 1
LINE 2
LINE 3
LINE 4
UPS
Ethernet ports
(RJ-45)
Power
connection
E1/T1
(RJ-48C)
19868
Fiber optic
port