8 — B-0404-A unit data sheet
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 8-5
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
Note
(1)
Full-duplex operation and auto-negotiation or manual setting by operator of Ethernet interface
line rate is also supported.
8.5 B-0404-A LEDs
Figure 8-2 shows the B-0404-A LEDs.
Figure 8-2 B-0404-A LEDs
Tables 8-5 provide business ONT LED descriptions.
Table 8-5 B-0404-A LED descriptions
19999
PWR
BTRY
FAIL
DATA
NTWK
MGMT
E1/T1
PWR BTRY FAIL DATA NTWK
MGMT E1/T1
Indicator Color Description
PWR Off
Green
No power available
Power is available
BTRY Off
Red
Red flashing
Battery power is not being used
Battery power is being used
Battery power is low or battery is being replaced
FAIL Off
Red
Equipment is 100% operational
Equipment failure or ONT not ranged/synchronized
DATA Off
Green
No link or data link not provisioned
Data link active
NTWK Off
Green
1490 nm data path is unavailable
1490 nm data path is available
MGMT Off
Green
Green flashing
No communication between P-OLT and the ONT
Full communication between P-OLT and the ONT
ONT is disabled
E1/T1 Off
Green
E1/T1 not provisioned
E1/T1 link operational