NTP 107 — Replace a B-2404-P business ONT
NTP 107-4 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Table NTP 107-1: Pin assignments on the 8-pin connector
iii Plug the optional 8-pin Molex output power cord in to the power connector.
8 If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP 134 for more information about
fiber optic handling, inspection, and cleaning.
9 Connect the SC/APC adaptor to the fiber optic port (DLP 125).
10 Verify the ONT LEDs and voltage status (DLP 127).
11 Activate and test the services (DLP 128).
12 STOP. This procedure is complete.
Pin # Definition Pin # Definition
1 Power input (+ 12V) 5 12 V power return
2 UPS status: On battery 6 Alarm ground
3 UPS status: Battery missing 7 UPS status: Replace battery
4 GNC / Optional frame ground 8 UPS status: Low battery
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.