5 — VoIP overview
5-70 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
enable_service_in_r
emote_hold
Specifies whether the ONT
supports supplementary services
such as three-way calling, call
hold display, and call transfer
when the call session is remotely
held.
The options are True/1/Yes and
False/0/No. If this parameter is
set to True, then ONT supports
the supplementary services. The
default is False. This attribute is
only supported in XML R4.4 and
later.
All lines of I-240W-S ONT should
be configured the same.
NYAll
except
package
C, D,
and E
No, value is
derived
from
FTP/default
line profile.
N/A
service_code_enabl
e_warm
Specifies the feature access
service code used by subscriber
to activate warmline. The user
agent must support at least two
service codes, as is typical in
most dialing plans. The default is
*53*. This reflects that fact You
can configure the parameter
when the enable_warmline
parameter is set to Subscriber.
NYAll
except
package
C, D, E,
and
I-240W-
S ONT
No, value is
derived
from
FTP/default
line profile.
N/A
service_code_disabl
e_warm
Specifies the feature access
service code used by subscriber
to deactivate warmline. The user
agent must support at least two
service codes, as is typical in
most dialing plans. The default is
#53#. This reflects that fact You
can configure the parameter
when the enable_warmline
parameter is set to Subscriber.
NYAll
except
package
C, D, E,
and
I-240W-
S ONT
No, value is
derived
from
FTP/default
line profile.
N/A
osi_timer Specifies the open switch
interval duration. The option is a
number from 0 to X, which
represents milliseconds. The
default is 900.
When set to 0, the ONT starts the
permanent signal treatment
immediately after the release
timer expires after a BYE is
received for an
incoming/outgoing call.
When set to non-zero, then after
release timer expires, the ONT
removes the loop current for the
specified time and then starts
the permanent signaling
treatment.
NYAll
except
package
C, D,
and E
No, value is
derived
from
FTP/default
line profile.
N/A
Parameter Description Mode
1
Mode
2
Device OMCIv2
support?
TL1 or CLI
parameters
(28 of 30)