EasyManua.ls Logo

Alcatel-Lucent 7360 - Page 470

Alcatel-Lucent 7360
1073 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 — ONT management using an ONT interface
6-38 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Table 6-10 Software download states
This section shows you how to check the status of a software download.
Prerequisites
The prerequisites are:
The user access level of the ONT is read-write.
The ONT is connected to the GPON.
The steps to access the interface are completed.
See Procedure 6-1 for HTTP interface using the first Ethernet port.
See Procedure 6-4 for CLI interface using the first Ethernet port.
Procedures using HTTP interface
The following procedure provides the steps to check the status of the software
download from the P-OLT to the ONT using the HTTP interface.
Download state Description
Idle There is no download activity.
Downloading Software is being downloaded from the P-OLT to the ONT.
Writing to flash Software updates are being written to memory.
Complete Software download is complete.
Note — The ONT changes from one operational state to another as
the software download progresses, as follows:
SW_DLD_IDLE, when there is no software download activity
SW_DLD_START, when the software download is initiated
SW_DLD_IP, when the software download is in progress
SW_DLD_DONE, when the software download is complete
SW_DLD_FAIL, when the software download failed
See section 6.6 for more information about checking the operational
state of an ONT.

Table of Contents

Related product manuals