NTP 101 — Replace a B-0404-A
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 NTP 101-5
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
9 If used, configure the SLID (DLP 129).
10 If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See DLP 134 for more information about
fiber optic handling, inspection, and cleaning.
11 Connect the fiber optic cable.
i Plug the OptiTap adaptor into the fiber optic port (DLP 124).
ii Plug the SC/APC adaptor into the fiber optic port (DLP 125).
12 Verify the ONT LEDs and voltage status (DLP 127).
13 Activate and test the services (DLP 128).
14 STOP. This procedure is complete.
Note — A new SLID or the old SLID may be used with the replacement
unit. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT.
Danger — Fiber optic cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.