NTP 140 — Replace an I-011G-P indoor ONT
NTP 140-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace an I-011G-P indoor ONT.
1 Deactivate the ONT services (DLP 131).
If you are using the SLID feature, this step is not required. The ONT and the
services can remain in service (IS).
2 Disconnect the Ethernet, fiber optic, coaxial, and power cables from the ONT
(DLP 132). For the location of the ports on the ONT; see Figure NTP 140-1.
Danger — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when connecting or removing the cables to or from the
ONT.
Caution — Keep ONTs out of direct sunlight. Prolonged exposure to
direct sunlight can damage the unit.
Note — Observe the following:
The ONT should be installed in accordance with the applicable
requirements of the NEC or CEC. Local authorities and practices take
precedent when there is conflict between the local standard and the
NEC or CEC.
The ONT must be installed by qualified personnel.
See I-011G-P detailed specifications in the unit data sheet for the
temperature ranges for this ONT.