Backup Services Commands
Page 34-5
5) Startup Timer Value
This field sets the time after system startup to wait for the primary entity to come up. If the
primary entity fails to come up within the defined time after system startup, the backup entity
will be activated. Acceptable values are in the range of 0-65535 seconds. The default value is
300 seconds.
6) Activate Timer Value
This field sets the amount of time that the primary entity must remain in a failed state before
the backup entity is activated. Acceptable values are in the range of 0-65535 seconds. The
default value is 10 seconds.
7) Restore Timer Value
This field sets the amount of time the primary entity returns and remains in an operational
state before the backup entity is deactivated. Acceptable values are in the range of 0-65535
seconds. The default value is 10 seconds.