Configuring the HRE-X Router Port
Page 9-28
For example, to assign register 3 to the Classical IP service enter
hrexassign 3 cip
at the system prompt. A screen similar to the following is displayed.
HRE-X RPM 3 configured for “CIP”; reboot to make effective.
As indicated on the screen, the register assignment will not take effect until the switch is
rebooted. If you use the hrexdisplay command after making a the register assignment shown
in the above example, a screen similar to the following is displayed.
Reg Configured Actual
------ ---------------- -----------------
1 Any Routing
2 Any Unused
3 CIP Routing
Configuration changed since last reboot.
This indicates that register 3 is assigned to the CIP service but is actually using the Routing
service. Also, the message at the bottom of the table indicates that the HRE-X configuration
has changed since the last reboot of the switch. After a reboot, the hrexdisplay command will
display the following screen.
Reg Configured Actual
------ ---------------- -----------------
1 Any Routing
2 Any Unused
3 Routing Routing