116 Rockwell Automation Publication 6000-TD004D-EN-P - November 2017
Chapter 2 Parameter Descriptions
Flying Start Motor Speed Search Timeout
Linear Number: P417
Default Value: 50 s
Minimum Value: 0 s
Maximum Value: 1000 s
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the Flying Start Motor Speed Search Timeout.
Flying Start Voltage Recovery Time (Low Speed Region)
Linear Number: P457
Default Value: 10.00 s
Minimum Value: 0.00 s
Maximum Value: 163.84 s
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the low speed region for Flying Start Voltage Recovery Time.
Flying Start Voltage Recovery Time (High Speed Region)
Linear Number: P459
Default Value: 10.00 s
Minimum Value: 0.00 s
Maximum Value: 163.84 s
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the high speed region for Flying Start Voltage Recovery
Time.
Flying Start Low/High Speed Regions Boundary
Linear Number: P463
Default Value: 16%
Minimum Value: 0%
Maximum Value: 100%
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the boundary for Flying Start-Low/High Speed Regions.