Rockwell Automation Publication 6000-TD004D-EN-P - November 2017 75
Parameter Descriptions Chapter 2
Motor Uab Voltage Scaling Factor
Linear Number: P205
Default Value: 153.0% (2.3 kV), 146.7% (2.4 kV),
175.9% (3.0 kV), 159.9% (3.3 kV),
175.8% (4.0 kV), 169.0% (4.16 kV),
146.5% (6.0 kV), 167.4% (6.3 kV),
159.8% (6.6 kV), 152.8% (6.9 kV),
158.1% (10.0 kV)
143.7% (11.0 kV)
Minimum Value: 0.00%
Maximum Value: 199.99%
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the Motor Uab Voltage Scaling Factor.
Motor Uac Voltage Scaling Factor
Linear Number: P206
Default Value: 153.0% (2.3 kV), 146.7% (2.4 kV),
175.9% (3.0 kV), 159.9% (3.3 kV),
175.8% (4.0 kV), 169.0% (4.16 kV),
146.5% (6.0 kV), 167.4% (6.3 kV),
159.8% (6.6 kV), 152.8% (6.9 kV),
158.1% (10.0 kV)
143.7% (11.0 kV)
Minimum Value: 0.00%
Maximum Value: 199.99%
Access Level: Setup, R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the Motor Uac Voltage Scaling Factor.
Digital Output Parameters
Digital Output #0 Memory Address
Linear Number: P300
Default Value: 99
Minimum Value: 0
Maximum Value: 500
Access Level: R&D
Read/Write: Read/Write
Modify Level: Online/Offline
This parameter sets the memory address for digital output #0.