Rockwell Automation Publication 6000-TD004D-EN-P - November 2017 175
Parameter Descriptions Chapter 2
P080 VFD Overload Current 0.00 399.99 120.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00 120.00 % On/Off Y Y
P081 VFD Overload Time 0 32767 60 60 60 60 60 60 60 60 60 60 60 60 s On/Off Y Y
P082 VFD Overload Cycle Time 0 32767 600 600 600 600 600 600 600 600 600 600 600 600 s On/Off Y Y
P087Switch Frequency Setting Enable Code0 1000000000000 Offline Y
P088Switch Frequency Setting 0 1000000000000 Offline Y
P089Skip Frequency Enable 0 1000000000000 On/OffYY
P090Skip Frequency 1 Lower Limit 0 75000000000000 On/OffYY
P091Skip Frequency 1 Upper Limit 0 75000000000000 On/OffYY
P092Skip Frequency 2 Lower Limit 0 75000000000000 On/OffYY
P093Skip Frequency 3 Upper Limit 0 75000000000000 On/OffYY
P094Fan Control Mode 0 2000000000000 OfflineYY
P095Fan Control Group #1 Fan Number0 10000000000000 OfflineYY
P096Fan Control Group #2 Fan Number0 10000000000000 OfflineYY
P097Fan Control Group #3 Fan Number0 10000000000000 OfflineYY
P098Fan Control Group #4 Fan Number0 10000000000000 OfflineYY
P099 Fan Control Main Cooling Fan Cycle Time 0 14400 720 720 720 720 720 720 720 720 720 720 720 720 hr On/Off Y Y
P100 Fan Control Redundant Fan Working
Time
0 14400111111111111hrOn/OffYY
P101 Fan Control Fan Feedback Delay 0 1000 200 200 200 200 200 200 200 200 200 200 200 200 100ms On/Off Y Y
P102Fan Control Fan Stop Delay 0 10111111111111mOn/OffYY
P103Pre-charge Enable 0 1000000000000 On/OffYY
P104Pre-charge Feedback Delay 0 100202020202020202020202020100 msOn/Off Y
P105Pre-charge DC Bus Threshold 0 100808080808080808080808080%On/Off Y
P106 Fan Control Transformer Cabinet Fan
Quantity Upper Limit
0 16101010101010101010101010 On/OffYY
P107 VFD Overload Current Offset 0.00 399.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 % On/Off Y
P108 Motor Overload Current Offset 0.00 399.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 4.99 % On/Off Y
P110 Heating Current Threshold 0.00 399.99 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 110.00 % On/Off Y
P111Slip Compensation Enable 0 1000000000000 On/Off Y
P113Flying Start-Initial Output Voltage0 100888888888888%On/OffYY
P114 Flying Start-Current Comparison Delay
For Motor Speed Search
0 5000 500 500 500 500 500 500 500 500 500 500 500 500 ms On/Off Y Y
No. Name Min. Max. Default Values Units Modify
Root
Access
2300V 2400V 3000V 3300V 4000V 4160V 6000V 6300V 6600V 6900V 10000V 11000V U S R