EasyManua.ls Logo

AudioCodes Mediant 800 - Page 1171

AudioCodes Mediant 800
1482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER69 Testing SIP Signaling Calls
Mediant 800 Gateway & E-SBC | User's Manual
3. Configure a test call according to the parameters described in the table below.
4. Click Apply, and then save your settings to flash memory.
Table 69-1: Test Call Rules Table Parameter Descriptions
Parameter Description
Common
'Index' Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
'Endpoint URI'
endpoint-uri
[Test_Call_EndpointURI]
Defines the endpoint's URI. This can be defined as a user
or user@host. The device identifies this endpoint only by
the URI's user part. The URI's host part is used in the
SIP From header in REGISTER requests.
The valid value is a string of up to 150 characters. By
default, the parameter is not configured.
Note: The parameter is mandatory.
'Called URI'
called-uri
[Test_Call_CalledURI]
Defines the destination (called) URI (user@host).
The valid value is a string of up to 150 characters. By
default, the parameter is not configured.
'Route By'
route-by
[Test_Call_RouteBy]
Defines the type of routing method. This applies to
incoming and outgoing calls.
[1] IP Group = (Default) Calls are matched by (or
routed to) an IP Group. To specify the IP Group, see
the 'IP Group' parameter in the table.
[2] Dest Address = Calls are matched by (or routed
to) a destination IP address. To configure the
address, see the 'Destination Address' parameter in
the table.
Note:
If configured to Dest Address: