EasyManuals Logo

AudioCodes Mediant 800 User Manual

AudioCodes Mediant 800
1482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1472 background imageLoading...
Page #1472 background image
CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
If you have not configured an Authentication server,
the device uses the Local Users table to authenticate
the user.
'Behavior upon Authentication
Server Timeout'
configure system >
mgmt-auth > timeout-
behavior
[MgmtBehaviorOnTimeout]
Defines the device's response when a connection timeout
occurs with the LDAP/RADIUS server.
[0] Deny Access = User is denied access to the
management platform.
[1] Verify Access Locally = (Default) Device verifies
the user's credentials in its Local Users table (local
database).
Note: The parameter is applicable to LDAP- and
RADIUS-based management-user login authentication.
'Default Access Level'
configure system >
mgmt-auth > default-
access-level
[DefaultAccessLevel]
Defines the default access level for the device when the
LDAP/RADIUS response doesn't include an access level
attribute for determining the user's management access
level.
The valid range is 0 to 255. The default is 200 (i.e.,
Security Administrator).
Note:
The parameter is applicable to LDAP- and RADIUS-
based management-user login authentication and
authorization.
If a user is not associated with any LDAP Group (at
the LDAP server), the device automatically uses the
value of this parameter as the access level.
RADIUS Parameters
The RADIUS parameters are described in the table below.
Table 72-71:RADIUS Parameters
Parameter Description
General RADIUS Parameters
'Enable RADIUS Access
Control'
configure system >
radius settings >
enable
[EnableRADIUS]
Enables the RADIUS application.
[0] Disable (default)
[1] Enable
Note: For the parameter to take effect, a device reset is
required.
[RadiusTrafficType] Defines the device's network interface for communicating
(RADIUS traffic) with the RADIUS server(s).
[0] = (Default) OAMP
[1] = Control
- 1432 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing