Parameter Description
'Status' (Read-only) Displays the status of the host associated with
the Web service.
"Connected": At least one of the hosts is connected.
"Disconnected": All hosts are disconnected.
'Active Group' (Read-only) Displays the currently active Group (by ID) that
is associated with the Web service. This is the host group to
where the device is currently sending traffic.
'Active Host' (Read-only) Displays the currently active host (by name) that
is associated with the Web service. This is the host (within
the active group) to where the device is currently sending
traffic.
Note: If traffic is sent to the hosts in a round-robin fashion
(i.e., 'Policy in Group' parameter is configured to Round
Robin), then this field displays "NA".
Configuring Remote HTTP Hosts
The HTTP Remote Hosts table lets you configure up to 10 remote HTTP hosts per Remote Web
Service. The HTTP Remote Hosts table is a "child" of the Remote Web Services table (configured
in Configuring Remote Web Services).
The following procedure describes how to configure HTTP Remote hosts through the Web
interface. You can also configure it through ini file [HTTPRemoteHosts] or CLI (configure
system > http-services > http-remote-hosts).
To configure a remote HTTP host:
1. Open the Remote Web Services table (Setup menu > IP Network tab > Web Services folder
> Remote Web Services).
2. In the table, select the required remote Web service index row, and then click the HTTP
Remote Hosts link located below the table; the HTTP Remote Hosts table appears.
3. Click New; the following dialog box appears:
4. Configure an HTTP remote host according to the parameters described in the table below.
5. Click Apply, and then save your settings to flash memory.
- 263 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals