CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
For the parameter to take effect, a device reset is
required.
The parameter is applicable only to ISDN PRI.
To enable the parameter per trunk, see the
EnableTDMOverIPforTrunk parameter.
[EnableTDMOverIPforTrunk] Enables TDM tunneling for a specific trunk. For a
description of the parameter, see EnableTDMoverIP.
iso8859-charset
[ISO8859CharacterSet]
Defines the ISO 8859 character set type (languages) for
representing the alphanumeric string of the calling name
(caller ID) in the forwarded message, for IP-to-Tel and
Tel-to-IP calls.
[0] = No Accented - proprietary method where
incoming INVITE messages with any accented
characters (e.g., á, é, í, ó, and ü), which are
represented in a 2-byte unicode character, are
translated to Latin-only, which are normal one-byte
ASCII characters (a, e, i, o, and u, respectively).
[1] = Western European (Default)
[2] = Central European
[3] = South European
[4] = North European
[5] = Cyrillic
[6] = Arabic
[7] = Hebrew
[8] = Turkish
'Time to Wait before Dialing'
[WaitForDialTime]
Defines the delay after hook-flash is generated and until
dialing begins. Applies to call transfer (i.e., the parameter
TrunkTransferMode is set to 3) on CAS protocols.
The valid range (in milliseconds) is 0 to 20,000 (i.e., 20
seconds). The default is 1,000 (i.e., 1 second).
Note: The parameter is also applicable to analog inter-
faces. For more information, see FXO and FXS Para-
meters on page1376.
TDM Bus and Clock Timing Parameters
The TDM Bus parameters are described in the table below.
Table 72-53:TDM Bus and Clock Timing Parameters
Parameter Description
TDM Bus Parameters
Digital PCM
- 1337 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing