CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
■ The parameter applies only to rejected responses
received from the remote network; not rejected
responses generated by the device (except for 404).
■ The response codes 401 and 407 are considered
authentication failures and therefore, are not applicable
to this parameter.
OCSP Parameters
The Online Certificate Status Protocol (OCSP) parameters are described in the table below.
Table 72-29:OCSP Parameters
Parameter Description
'Enable OCSP Server'
configure network > ocsp > enable
[OCSPEnable]
Enables or disables certificate
checking using OCSP.
■ [0] Disable (default)
■ [1] Enable
For a description of OCSP, see
Configuring Certificate Revocation
Checking (OCSP).
'Primary Server IP'
configure network > ocsp > server-ip
[OCSPServerIP]
Defines the IP address of the OCSP
server.
The default IP address is 0.0.0.0.
'Secondary Server IP'
configure network > ocsp > secondary-
server-ip
[OCSPSecondaryServerIP]
Defines the IP address (in dotted-
decimal notation) of the secondary
OCSP server (optional).
The default IP address is 0.0.0.0.
'Server Port'
configure network > ocsp > server-port
[OCSPServerPort]
Defines the OCSP server's TCP
port number.
The default port number is 2560.
'Default Response When Server Unreachable'
configure network > ocsp > default-
response
[OCSPDefaultResponse]
Determines whether the device
allows or rejects peer certificates
when the OCSP server cannot be
contacted.
■ [0] Reject (default)
■ [1] Allow
Proxy, Registration and Authentication Parameters
The proxy server, registration and authentication SIP parameters are described in the table below.
- 1213 -