CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
For the parameter to take effect, a device reset is
required.
configure voip > interface
fxs-fxo > time-to-sample-
analog-line-voltage
[TimeToSampleAnalogLineVoltage]
Defines the frequency at which the analog line
voltage is sampled (after offhook), for detection of the
current disconnect threshold.
The valid range is 100 to 2500 msec. The default is
1000 msec.
Note:
The parameter is applicable only to FXO
interfaces.
For the parameter to take effect, a device reset is
required.
SBC Parameters
The SBC and CRP parameters are described in the table below.
Table 72-66:SBC and CRP Parameters
Parameter Description
CRP-specific Parameters
configure voip > application >
enable-crp
[EnableCRPApplication]
Enables the CRP application.
[0] = Disable (default)
[1] = Enable
Note: For the parameter to take effect, a
device reset is required.
'CRP Survivability Mode'
configure voip > sbc settings >
crp-survivability-mode
[CRPSurvivabilityMode]
Defines the CRP mode.
[0] Standard Mode (default)
[1] Always Emergency Mode
[2] Auto-answer REGISTER
'CRP Gateway Fallback'
configure voip > sbc settings >
crp-gw-fallback
[CRPGatewayFallback]
Enables fallback routing from the proxy
server to the Gateway (PSTN).
[0] Disable (default)
[1] Enable
SBC-specific Parameters
configure voip > application >
enable-sbc
[EnableSBCApplication]
Enables the Session Border Control (SBC)
application.
[0] = Disable
[1] = Enable (default)
Note:
For the parameter to take effect, a
device reset is required.
- 1401 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing