Page #1003 background image
CHAPTER49 Automatic Provisioning
Mediant 800 Gateway & E-SBC | User's Manual
AutoCmpFileUrl = 'https://www.company.com/sw.cmp'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# auto-firmware 'http://www.company.com/sw.cmp'
c. Automatic Update of Call Progress Tone file:
ini File:
CptFileURL = 'https://www.company.com/call_progress.dat'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# call-progress-tones 'http://www.company.com/call_
progress.dat'
d. Automatic Update of ini configuration file:
ini File:
IniFileURL = 'https://www.company.com/config.ini'
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# voice-configuration
'http://www.company.com/config.ini'
e. Enable Cyclical Redundancy Check (CRC) on downloaded ini file:
ini File:
AUPDCheckIfIniChanged = 1
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# crc-check regular
4. Power down and then power up the device.
Automatic Update from Remote Servers
This example describes how to configure the Automatic Update feature where files are stored and
downloaded from different file server types. The example scenario includes the following:
FTPS server at ftpserver.corp.com for storing the License Key file. The login credentials to the
server are username "root" and password "wheel".
HTTP server at www.company.com for storing the configuration file.
- 963 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing