EasyManua.ls Logo

AudioCodes Mediant 800 - Call Waiting Parameters

AudioCodes Mediant 800
1482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Call Waiting Parameters
The call waiting parameters are described in the table below.
Table 72-42:Call Waiting Parameters
Parameter Description
'Enable Call Waiting'
configure voip >
gateway dtmf-supp-
service supp-service-
settings > call-
waiting
[EnableCallWaiting]
Enables the Call Waiting feature.
[0] Disable
[1] Enable (default)
Digital interfaces: If enabled and the device initiates a Tel-to-
IP call to a destination that is busy, it plays a call waiting
ringback tone to the caller. The tone is played only if the
destination returns a 182 "Queued" SIP response.
FXS interfaces: If enabled, when an FXS interface receives a
call on a busy endpoint, it responds with a 182 response (and
not with a 486 busy). The device plays a call waiting
indication signal. When hook-flash is detected, the device
switches to the waiting call. The device that initiated the
waiting call plays a call waiting ringback tone to the calling
party after a 182 response is received.
Note:
The device's Call Progress Tones (CPT) file must include
a Call Waiting ringback tone-- for analog interfaces: (caller
side) and a call waiting tone (called side, FXS only).
FXS interfaces: The EnableHold parameter must be
enabled on both the calling and the called side.
Analog interfaces: You can use the table parameter
CallWaitingPerPort to enable Call Waiting per port.
Analog interfaces: For information on the Call Waiting
feature, see Enabling Call Waiting.
configure voip > sip-
definition settings >
send-180-for-call-
waiting
[Send180ForCallWaiting]
Determines the SIP response code for indicating Call
Waiting.
[0] = (Default) Use 182 Queued response to indicate call
waiting.
[1] = Use 180 Ringing response to indicate call waiting.
'Number of Call Waiting
Indications'
configure voip >
gateway dtmf-supp-
service supp-service-
settings > nb-of-cw-
ind
[NumberOfWaitingIndication
s]
Defines the number of call waiting indications that are played
to the called telephone that is connected to the device for Call
Waiting.
The valid range is 1 to 100 indications. The default is 2.
Note: The parameter is applicable only to FXS ports.
'Time Between Call Waiting
Indications'
Defines the time (in seconds) between consecutive call
waiting indications for call waiting.
The valid range is 1 to 100. The default is 10.
- 1309 -