CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
configure troubleshoot
> cdr > call-duration-
units
[CallDurationUnits]
Defines the unit of measurement for call duration
("Duration" field) in CDRs generated by the device.
■ [0] Seconds (default)
■ [1] Deciseconds
■ [2] Centiseconds
■ [3] Milliseconds
The parameter applies to CDRs for Syslog, RADIUS,
local-device storage, and CDR history displayed in the
Web interface.
'CDR Syslog Sequence
Number'
configure system > cdr
> cdr-seq-num
[CDRSyslogSeqNum]
Enables or disables the inclusion of the sequence number
(S=) in CDR Syslog messages.
■ [0] Disable
■ [1] Enable (default)
[SendAcSessionIDHeader] Enables the use of the Global Session ID in SIP messages
(AC-Session-ID header), which is a unique identifier of the
call session, even if it traverses multiple devices.
■ [0] = (Default) Disables the feature. The device sends
outgoing SIP messages without a Global Session ID
(even if a Global Session ID was received in the
incoming SIP message).
■ [1] = Enables the feature. If the device receives an
incoming SIP message containing a Global Session
ID, it sends the same Global Session ID in the
outgoing SIP message. If the incoming SIP message
does not contain a Global Session ID or if a new
session is initiated by the device, the device generates
a new, unique Global Session ID and adds it to the
outgoing SIP message.
For more information, see Enabling Same Call Session ID
over Multiple Devices on page1125.
'Activity Types to Report via
Activity Log Messages'
configure troubleshoot
> activity-log
[ActivityListToLog]
Defines the operations (activities) performed in the Web
interface that are reported to a Syslog server.
■ [pvc] Parameters Value Change = Changes made
on-the-fly to parameters and tables, and Configuration
file load. Note that the ini file parameter,
EnableParametersMonitoring can also be used to set
this option.
■ [afl] Auxiliary Files Loading = Loading of Auxiliary
files.
■ [dr] Device Reset = Resetting the device from the
Maintenance Actions page.
Note: For this option to take effect, a device reset is
required.
■ [fb] Flash Memory Burning = Saving configuration
with burn to flash from the Maintenance Actions page.
- 1194 -