CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
Note:
■ This functionality can be configured per Proxy Set in
the Proxy Sets table (see Configuring Proxy Sets).
■ When enabled, NAPTR/SRV queries are used to
discover Proxy servers even if the parameter
DNSQueryType is disabled.
'Use Gateway Name for OPTIONS'
configure voip > sip-
definition proxy-and-
registration > use-gw-
name-for-opt
[UseGatewayNameForOptions]
Determines whether the device uses its IP address or
string name ("gateway name") in keep-alive SIP
OPTIONS messages (host part of the Request-URI).
To configure the "gateway name", use the
SIPGatewayName parameter. The device uses the
OPTIONS request as a keep-alive message with its
primary and redundant SIP proxy servers (i.e., the
EnableProxyKeepAlive parameter is set to 1).
■ [0] No = (Default) Device's IP address is used in
keep-alive OPTIONS messages.
■ [1] Yes = Device's "gateway name" is used in keep-
alive OPTIONS messages.
■ [2] Server = Device's IP address is used in the
From and To headers in keep-alive OPTIONS
messages.
'User Name'
configure voip > sip-
definition proxy-and-
registration > user-name-
4-auth
[UserName]
Defines the username for registration and Basic/Digest
authentication with a Proxy/Registrar server.
The valid value is a string of up to 60 characters. By
default, no value is defined.
Note:
■ The parameter is applicable only to the Gateway
application.
■ The parameter is applicable only if single device
registration is used (i.e., the parameter
AuthenticationMode is set to authentication per
gateway).
■ Analog interfaces: Instead of configuring the
parameter, the Authentication table can be used
(see Authentication).
'Password'
configure voip > sip-
definition proxy-and-
registration > password-
4-auth
[Password]
Defines the password for Basic/Digest authentication
with a Proxy/Registrar server. A single password is
used for all device ports.
The default is 'Default_Passwd'.
Note: Analog interfaces: Instead of configuring the
parameter, the Authentication table can be used (see
Authentication).
'Cnonce' Defines the Cnonce string used by the SIP server and
client to provide mutual authentication.
The value is free format, i.e., 'Cnonce = 0a4f113b'. The
default is 'Default_Cnonce'.
- 1218 -