CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
[5] INFO (Lucent) = Sends proprietary SIP
INFO message with Hook-Flash indication.
The device sends the INFO message as fol-
lows:
Content-Type: application/hook-flash
Content-Length: 11
signal=hf
[6] INFO (NetCentrex) = Sends proprietary SIP
INFO message with Hook-Flash indication. The
device sends the INFO message as follows:
Content-Type: application/dtmf-relay
Signal=16
Where 16 is the DTMF code for hook flash.
[7] INFO (HUAWEI) = Sends a SIP INFO
message with Hook-Flash indication. The
device sends the INFO message as follows:
Content-Length: 17
Content-Type: application/sscc
event=flashhook
Note:
Digital interfaces: The device can interwork
DTMF HookFlashCode to SIP INFO messages
with Hook Flash indication.
FXO interfaces support only the receipt of RFC
2833 Hook-Flash signals and INFO [1] type.
FXS interfaces send Hook-Flash signals only if
the EnableHold parameter is set to 0.
configure voip > gw dtmf-
and-suppl > gw digitalgw
digital-gw-parameters >
flash-from-media-ip
[HookFlashFromMediaIP]
Defines the device’s handling of hook-flash
telephony events that are received in the media
(RTP) from the IP side (typically, RFC 2833) and
then sent to the PSTN CAS side.
[0] = (Default) The device ignores incoming
hook-flash events from the media IP.
[1] = The device generates a wink to the CAS
side when it receives a hook-flash event from
the media IP.
Note: The parameter is applicable only to E1/T1
CAS.
'Min. Flash-Hook Detection Period'
configure voip > interface
fxs-fxo > min-flash-hook-
time
[MinFlashHookTime]
Defines the minimum time (in msec) for detection of
a hook-flash event. Detection is guaranteed for
hook-flash periods of at least 60 msec (when
setting the minimum time to 25). Hook-flash signals
that last a shorter period of time are ignored.
The valid range is 25 to 300. The default is 300.
Note: