CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
Digital interfaces: or E1 CAS MFC-R2
variants (which don't support terminating digit
for the called party number, usually I-15), the
parameter and the DigitMapping parameter
are ignored. Instead, you can define a Dial
Plan template per trunk using the parameter
CasTrunkDialPlanName_x (or in the Trunk
Settings page).
The parameter can also be configured in a Tel
Profile.
For more information on the Dial Plan file, see
Dialing Plans for Digit Collection.
configure voip > gateway
manipulation settings >
tel2ip-src-nb-map-dial-index
[Tel2IPSourceNumberMappingDialPlanIn
dex]
Defines the Dial Plan index in the external Dial
Plan file for the Tel-to-IP Source Number Mapping
feature.
The valid value range is 0 to 7, defining the Dial
Plan index [Plan x] in the Dial Plan file. The
default is -1 (disabled).
For more information on this feature, see
Modifying ISDN-to-IP Calling Party Number
using Dial Plan File.
'Digit Mapping Rules'
configure voip > gateway dtmf-
supp-service dtmf-and-dialing
> digitmapping
[DigitMapping]
Defines the digit map pattern. If the digit string
(i.e., dialed number) matches one of the patterns
in the digit map, the device stops collecting digits
and establishes a call with the collected number.
For digital interfaces: This is used to reduce the
dialing period for ISDN overlap dialing.
The digit map pattern can contain up to 52 options
(rules), each separated by a vertical bar (|). The
maximum length of the entire digit pattern is 152
characters. The available notations include the
following:
[n-m]: Range of numbers (not letters).
. (single dot): Repeat digits until next notation
(e.g., T).
x: Any single digit.
T: Dial timeout (configured by the
TimeBetweenDigits parameter).
- 1295 -