CHAPTER72 Configuration Parameters Reference
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
Note: The parameter is applicable only to the Gateway
application (digital interfaces).
'AMD Mode'
configure voip > sip-
definition settings > amd-
mode
[AMDmode]
Global parameter that enables the device to
disconnect the IP-to-Tel call upon detection of an
answering machine on the Tel side. You can also
configure this feature per specific calls, using IP
Profiles (IpProfile_AmdMode). For a detailed
description of the parameter and for configuring this
feature in the IP Profiles table, see Configuring IP
Profiles.
Note:
■ The parameter is applicable only to the Gateway
application (digital interfaces).
■ If this feature is configured for a specific IP Profile,
the settings of this global parameter is ignored for
calls associated with the IP Profile.
Energy Detector Parameters
'Enable Energy Detector'
configure voip > media
ipmedia > energy-detector-
enable
[EnableEnergyDetector]
Enables the Energy Detector feature. This feature
generates events (notifications) when the signal
received from the PSTN is higher or lower than a user-
defined threshold (defined by the
EnergyDetectorThreshold parameter).
■ [0] Disable (default)
■ [1] Enable
'Energy Detector Quality Factor'
configure voip > media
ipmedia > energy-detector-
sensitivity
[EnergyDetectorQualityFactor]
Defines the Energy Detector's sensitivity level.
The valid range is 0 to 10, where 0 is the lowest
sensitivity and 10 the highest sensitivity. The default is
4.
'Energy Detector Threshold'
configure voip > media
ipmedia > energy-detector-
threshold
[EnergyDetectorThreshold]
Defines the Energy Detector's threshold. A signal
below or above this threshold invokes an 'Above' or
'Below' event.
The threshold is calculated as follows:
Actual Threshold = -44 dBm +
(EnergyDetectorThreshold * 6)
The valid value range is 0 to 7. The default is 3 (i.e., -26
dBm).
Pattern Detection Parameters
Note: For an overview on the pattern detector feature for TDM tunneling, see DSP Pattern
Detector.
'Enable Pattern Detector'
[EnablePatternDetector]
Enables the Pattern Detector (PD) feature.
■ [0] Disable (default)
■ [1] Enable
- 1429 -