EasyManuals Logo

AudioCodes Mediant 800 User Manual

AudioCodes Mediant 800
1482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #168 background imageLoading...
Page #168 background image
CHAPTER14 Security
Mediant 800 Gateway & E-SBC | User's Manual
3. Configure the TLS Context according to the parameters described in the table below.
4. Click Apply, and then reset the device with a save-to-flash for your settings to take effect.
Table 14-1: TLS Contexts Parameter Descriptions
Parameter Description
General
'Index'
tls
[TLSContexts_Index]
Defines an index number for the new table row.
Note:
Each row must be configured with a unique index.
Index 0 ("default") is the default TLS Context.
'Name'
name
[TLSContexts_Name]
Defines a descriptive name, which is used when associating
the row in other tables.
The valid value is a string of up to 31 characters.
Note:
The parameter value cannot contain a forward slash (/).
The default TLS Context (Index 0) is named "default".
'TLS Version'
tls-version
[TLSContexts_TLSVersion]
Defines the supported SSL/TLS protocol version. Clients
attempting to communicate with the device using a different
TLS version are rejected.
[0] Any - Including SSLv3 = (Default) SSL 3.0 and all
TLS versions are supported.
[1] TLSv1.0 = Only TLS 1.0.
[2] TLSv1.1 = Only TLS 1.1.
[3] TLSv1.0 and TLSv1.1 = Only TLS 1.0 and TLS 1.1.
[4] TLSv1.2 = Only TLS 1.2.
[5] TLSv1.0 and TLSv1.2 = Only TLS 1.0 and TLS 1.2.
[6] TLSv1.1 and TLSv1.2 = Only TLS 1.1 and TLS 1.2.
[7] TLSv1.0 TLSv1.1 and TLSv1.2 = Only TLS 1.0, TLS
1.1 and TLS 1.2 (excludes SSL 3.0).
'DTLS Version'
[TLSContexts_DTLSVersion]
Defines the Datagram Transport Layer Security (DTLS)
version, which is used to negotiate keys for WebRTC calls.
[0] Any (default)
- 128 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals