CHAPTER18 Core Entities
Mediant 800 Gateway & E-SBC | User's Manual
Parameter Description
The parameter is applicable only to the SBC
application.
'Used By Routing Server'
used-by-routing-server
[SRD_UsedByRoutingServer]
Enables the SRD to be used by a third-party routing
server for call routing decisions.
[0] Not Used (default)
[1] Used
For more information on the third-party routing server
feature, see Centralized Third-Party Routing Server.
'Dial Plan'
sbc-dial-plan-name
[SRD_SBCDialPlanName]
Assigns a Dial Plan to the SRD. The device searches
the Dial Plan for a dial plan rule that matches the
source number and if not found, for a rule that
matches the destination number. If a matching dial
plan rule is found, the rule's tag is used in the routing
and/or manipulation processes as source and/or
destination tags.
To configure Dial Plans, see Configuring Dial Plans.
'CAC Profile'
cac-profile
[SRD_AdmissionProfile]
Assigns a Call Admission Control Profile (CAC rules)
to the SRD.
By default, no value is defined.
To configure CAC Profiles, see Configuring Call
Admission Control on page778.
Registration
'Max. Number of Registered Users'
max-reg-users
[SRD_MaxNumOfRegUsers]
Defines the maximum number of users belonging to
the SRD that can register with the device.
The default is -1, which means that the number of
allowed user registrations is unlimited.
Note: The parameter is applicable only to the SBC
application.
'User Security Mode'
block-un-reg-users
[SRD_BlockUnRegUsers]
Defines the blocking (reject) policy for incoming SIP
dialog-initiating requests (e.g., INVITE messages)
from registered and unregistered users belonging to
the SRD.
[0] Accept All = (Default) Accepts requests from
registered and unregistered users.
[1] Accept Registered Users = Accepts
requests only from users registered with the
device. Requests from users not registered are
rejected.