CHAPTER21 SIP Message Manipulation
Mediant 800 Gateway & E-SBC | User's Manual
For a detailed description of supported regex syntax, refer to the Syntax for SIP
Message Manipulation Reference Guide
Pre-Parsing Manipulation is configured using two tables with "parent-child" relationship:
Pre-Parsing Manipulation Sets table ("parent"): Defines a descriptive name for the Pre-Parsing
Manipulation Set.
Pre-Parsing Manipulation Rules table ("child"): Defines the actual manipulation rule. You can
configure up to 10 rules per Pre-Parsing Manipulation Set.
The following procedure describes how to configure Pre-Parsing Manipulation Sets through the
Web interface. You can also configure it through other management platforms:
Pre-Parsing Manipulation Sets table: ini file [PreParsingManipulationSets] or CLI
(configure voip > message pre-parsing-manip-sets)
Pre-Parsing Manipulation Rules table: ini file [PreParsingManipulationRules] or CLI
(configure voip > message pre-parsing-manip-rules)
To configure Pre-Parsing Manipulation Sets:
1. Open the Pre-Parsing Manipulation Sets table (Setup menu > Signaling & Media tab >
Message Manipulation folder > Pre-Parsing Manipulation Sets).
2. Click New; the following dialog box appears:
3. Configure a Pre-Parsing Manipulation Set name according to the parameters described in the
table below.
4. Click Apply.
Table 21-4: Pre-Parsing Manipulation Set Table Parameter Descriptions
Parameter Description
'Index'
[PreParsingManipulationSets_
Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
'Name'
name
[PreParsingManipulationSets_
Name]
Defines a descriptive name, which is used when
associating the row in other tables.
The valid value is a string of up to 40 characters.
Note:
Each row must be configured with a unique name.
The parameter value cannot contain a forward slash (/).