Managed Opus or Managed G.729: If the SBC detects WAN network impairments during a
call using the Opus or G.729 coder between the Enterprise SBC and Access SBC, it can
adjust the coder's attributes (e.g., bit rate) for that specific call to ensure high voice quality is
maintained. The advantage of these coders is that their bit rate can change dynamically
according to bandwidth availability. This mode is useful for unstable networks, allowing the
coders to dynamically adapt to adverse network conditions.
For Managed Opus, the Enterprise SBC performs transcoding from G.711 (used between
Enterprise phones and SBC) to Opus (used between Enterprise and Access SBCs). For
Managed G.729, the G.729 coder is used by all the involved entities and therefore, transcoding
is not needed. For Managed G.729 operating in an MPLS environment, voice quality can also be
maintained, as mentioned previously.
Figure 37-1: VoIPerfect Managed Opus
Figure 37-2: VoIPerfect Managed G.729
Configuration of the Enterprise SBC:
Coder Groups table (see Configuring Coder Groups): Coder Group with Opus or G.729
(depending on Managed coder)
Allowed Audio Coders Groups table (see Configuring Allowed Audio Coder Groups):
Allowed Audio Coder Group with Opus or G.729 (depending on Managed coder)
IP Profiles table (see Configuring IP Profiles):
(Managed Opus Only) 'Extension Coders Group': Select the Coders Group for Opus
'Allowed Audio Coders': Select the Allowed Audio Coders Group with Opus or G.729
(depending on Managed coder)
'Allowed Coders Mode': Restriction
'Voice Quality Enhancement': Enable
'RTCP Feedback': Feedback On
(Managed Opus Only) 'Max Opus Bandwidth': 0
(Managed G.729 Only) 'Jitter Compensation': Enable
(Managed G.729 Only) 'RTCP Mode': Generate Always
(Managed G.729 Only) 'Dynamic Jitter Buffer Minimum Delay': 40
(Managed G.729 Only) 'Jitter Buffer Max Delay': 500
(Managed G.729 Only) MPLSMode (ini file parameter): 0 if no MPLS; 1 if operating in an
MPLS environment
- 867 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals