CHAPTER41 HA Configuration
Mediant 800 Gateway & E-SBC | User's Manual
2. In the table, select the required index row (monitored row), and then click the HA Network
Monitor Peers Status link located below the table; the HA Network Monitor Peers Status
table appears, displaying the reachability status of each destination ('Peer Destination
Address') of the monitored row, as shown in the below example:
The reachability status is displayed in the 'Peer Reachability Status' read-only field:
"Reachability unverified": The reachability status of the destination is currently
undetermined. In other words, the destination has never replied to the device's pings.
"Reachable": The device considers the destination as online (reachable). In other words,
the device has received a ping reply from the destination.
"Not reachable": The device considers the destination as offline (unreachable). In other
words, the number of consecutive failed pings equaled to (or was greater than) that
configured by the 'Ping Count' parameter.
"Terminated by ping error": The device is unable to send a ping to the destination (typically,
due to a routing issue or incorrect destination address). To resolve the problem, correct
your routing configuration or the address of the destination, and then enter the edit mode of
the HA network monitor row belonging to the destination and click Apply to refresh your
changes.
The 'Ping Loss Percentage' read-only field displays the percentage of pings sent to the
destination that failed to get a reply, in the last five minutes.
- 896 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals