Page 4–106
DURApulse GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
Chapter 4: AC Drive Parameters
Type Hex Addr Dec Addr
P4.49 reserved
n/a 0431 41074
Range/Units Default
n/a
n/a
Type Hex Addr Dec Addr
P4.50 Analog Output 1 (AO1)
n/a 0432 41075
Range/Units Default
0: Output Frequency (Hz)
1: Frequency Command (Hz)
2: Motor Speed (Hz)
3: Output Current (A
rms
)
4: Output Voltage (V)
5: DC Bus Voltage (V)
6: Power Factor (%)
7: Power (% rated)
8: AI1 (%)
9: AI2 (%)
10: AI3 (%)
11: RS485 AO
12: Comm Card AO
13: Fixed Value
0
NOTE: AO1 is a voltage output. To use AO1 as an analog current output, external resistance
needs to be supplied. See the detailed information in P4.53.
If only 1 analog current output is needed, consider using AO2. AO2 is capable of supplying a
true current output (no external resistors needed between the GS4 analog output and the other
device's analog input).
The Parameter memory can only be written to 109 times before a memory error will occur. This
memory error will not occur if using setting #11 or #12.
• Use setting #11 or #12 if the AO value will be changed frequently.
• Use setting #13 if the value will not be changed frequently.
DIP SW1 (above the terminals) sets AO1 to be either 0~10VDC output or -10 to +10VDC output.
For 0~10V switch setting: 0=0V; 5000=5V; 10,000=10V
For -10 to +10V setting: 0=-10V; 5000=0V; 10,000=10V
Setting #11: As 485 AO
Write to 26A0 hex (49889 dec) via the RS-485 port to control the output� 0~10,000 ==> 0~100%�
The register will not maintain the value, but the analog signal will remain (if you write a value of
5000 to 26A0h, the analog output will produce 5V but the register will read zero)� Writing via the
Ethernet cards will have no effect�
Setting #12: As COMM Card AO
Write to 26A0 hex (49889 dec) via the Ethernet card to control the output� 0~10,000 ==>
0~100%� The register will not maintain the value, but the analog signal will remain (if you write a
value of 5000 to 26A0h, the analog output will produce 5V but the register will read zero)� Writing
via RS-485 will have no effect�
Setting #13: Fixed Value
Adjust the value of P4�60 via the keypad to increase or decrease the analog output� Writing to
P4�60 via RS-485 or Ethernet does change the output value�
Type Hex Addr Dec Addr
P4.51 AO1 Gain
♦R/W 0433 41076
Range/Units (Format: 16-bit unsigned) Default
0�0~500�0%
100�0
Scaling factor for the analog output AO1. This parameter adjusts the analog voltage level of the
output.
NOTE: For 100% of gain via communications, write a value of 1000.