Page B–20
DuRApulse GS4 AC Drive User Manual – 1st Ed, Rev A - 10/20/2017
Appendix B: Optional I/O and Communication Cards
gs4-Cm-eneTip error Code for moniTor requesT
Status Code Extended Status Code Definition
0x00 The execution of service is successful�
0x01 0x0100
The connection is in progress or the connection is re-opened�
The code will be sent back when the source is trying to establish a
connection to the target but the target has already been connected�
0x01 0x0103
Does not support the combination of this transmission type and
trigger
The target does not support the defined combination of
transmission type and trigger� The router will not teminate the
connection, only the target end has to send back this extended
status code�
0x01 0x0106
Clash of control right
A connection takes the control, blocking the establishment of other
connections� When this device occupies the connection in this way,
only one connection will be allowed to control this device�
0x01 0x0107 Cannot find the corresponding target to connect
0x01 0x0108
Invalid network connection parameter
When the application program in the target does not support the
defined connection type, connection level, or there are too many
users, the extended status code will be sent back� Only the node on
target has to send back the extended status code�
0x01 0x0109
Invalid setting of the size of the on-line data exchange zone
This device does not support the setting of the current data
exchange zone� The setting can be too big or too small�
0x01 0x0111 RPI setting not supported
0x01 0x0113
The number of connections exceeds the maximum�
No further connections are able to connect to this device�
0x01 0x0114
The company ID does not match product code�
The product code or company ID marked in the electronic key logic
section does not match the record in the target device�
0x01 0x0115
Inconsistent product type
The product type marked in the electronic key logic section does
not match the record in the target device�
0x01 0x0116
Inconsistent version
The primary and secondary revised versions marked in the
electronic key logic section do not match the record in the target
device�
0x01 0x0315
Invalid section exists in the path�
The type or value of a section in the path is invalid� When the device
cannot interpret the path, it will respond with this extended status
code�
Cause of this error: Unidentifiable path type, unexpected section
type or other problems existing in the path�

Table of Contents

Other manuals for Automation Direct DURApulse GS4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automation Direct DURApulse GS4 and is the answer not in the manual?

Automation Direct DURApulse GS4 Specifications

General IconGeneral
BrandAutomation Direct
ModelDURApulse GS4
CategoryController
LanguageEnglish

Related product manuals