4.12 Scanning Image Defect Troubleshooting
4.12.1 Image defect examples
Fig. 2-15
4.12.2 Troubleshooting image defect
■ Light on the page
<User Check>
- Check whether the setting of the contrast does not become light.
- Clean the document table glass or ADF glass.
- Clean the CIS glass of the ADF.
Step Cause Remedy
1 White level calibration data
failure
Perform the acquisition of white level data.
(Function code 55)
2 First side or second side CIS
unit failure
Replace the first side or second side CIS
unit.
3 Main PCB failure Replace the main PCB ASSY.
Light on the page
(2-116)
Faulty registration
(2-117)
Dark
(2-117)
Completely blank
(2-118)
Vertical streaks
(2-118)
White vertical streaks
(2-118)
All black
(2-119)