2-92
Confidential
■ Image distortion
■ All one color
<User Check>
- Clean the corona wire of each drum unit for all four colors.
- Replace the drum unit with a new one.
<User Check>
- Replace the belt unit with a new one.
Step Cause Remedy
1 LED ASSY installation failure Install the LED ASSY properly and tighten
screws securely.
2 LED ASSY failure Replace the LED ASSY.
3 Main PCB failure Replace the main PCB ASSY.
Step Cause Remedy
1 Dirt on the GRID electrodes of
the main body or drum unit
Clean the GRID electrodes of the main body
or drum unit. (Refer to fig. 2-7 (P2-50) and
fig. 2-8 (P2-51))
2 Flat cable connection failure
of the LED ASSY
Reconnect the flat cable of LED ASSY
correctly.
3 LED flat cable failure Replace the LED flat cable.
4 LED control PCB failure Replace the LED control PCB ASSY.
5 High-voltage power supply
PCB failure
Replace the high-voltage power supply PCB
ASSY.
6 LED ASSY failure Replace the LED ASSY.
7 Main PCB failure Replace the main PCB ASSY.