ELECTRICAL
CAUTION SYSTEM
CAUTION SYSTEM
Two caution systems alert the operator when
an
abnormality occurs:
• Over-revolution Caution
• Low Oil Pressure Caution
Caution Type Lamp Buzzer Rev
*
Limiter
Over-revolution
Yes
No
Yes
Low oil pressure
Yes
Yes Yes
• Remote models only
Self Test
The caution lamp turns
ON
two seconds after
starting engine.
On
remote control models, the caution buzzer
sounds when ignition switch
is
turned
ON.
Buzzer
stops when engine starts and oil pressure switch
turns
OFF.
1. Caution lamp
004714
66
Over-Revolution Caution System
The
COl
unit engages the over-revolution limiter
above
6500 RPM.
• If the operator decreases engine speed to less
than approximately
6200
RPM
within 10 sec-
onds, the over-revolution caution control will
be
cancelled.
• If the engine
is
operated at a speed above 6500
RPM
for more than
10
seconds, the engine
speed will
be
automatically lowered to approxi-
mately
300
RPM
by intermittent ignition.
• During operation of the over-revolution caution
control, the caution lamp
is
ON.
To
cancel the over-revolution caution control
,
close the throttle to reduce engine speed below
approximately
2500
RPM
for more than one sec-
ond.
IMPORTANT:
In
NEUTRAL, the over-revolution
caution system activates at
4000
RPM
and the
caution lamp does not light.
To
cancel the neutral
rev-limiter, close throttle completely for more than
one second.