List of ADU events
G-8 Appendix G: System messages 98-150471-A02
0A05D-0 Antenna WARNING ISM warning The ISM has temporarily observed an
unusual situation for temperature or
voltage. No user interaction required. If
repeated after cooldown and reboot, check
if the ISM or cables around it are defective.
0A05E-0 Antenna WARNING Low elevation The antenna is not allowed to transmit
because the elevation is too low.
0A05F-0 Antenna WARNING Heading range Heading data range error. External heading
unit supplies unreliable data.
0A062-0 Antenna WARNING High elevation The antenna cannot perform acquisition in
gyro-free mode because the elevation is
too high.
0A065-0 Antenna ERROR Deploy/Stow Deploy/stow error. The antenna did not
properly unlock (deploy), or the stow switch
never closed (stow).
0A066-0 Antenna ERROR OMT error Problem with OMT. Temperature may be
too high. OMT cable may be broken.
Error code
(ID)
Unit Severity Description Explanation
Table G-1: ADU event messages (Continued)