COMSWITCH-II that control and route traffic between the ports. These commands consist of single letters
preceded by a <BREAK>.
The COMSWITCH-H has the following features:
Customer security provided by a password and dialback dialstring.
Bypass ("straight-through") hardware that allows cabling and other basic installation procedures to be
verified prior to configuration.
A nonvolatile RAM that stores configuration data (baud rates, password, and dialstring).
A clock/calendar IC, after being set, provides date and time.
1.1.2 212A Intelligent Modem
The COMSWITCH-II is designed to function with a 212A compatible autodial modem with a Hayes instruction
set (a non-autodial modem can be used, providing the dialback feature is not required). A modem provides full
duplex transmission and reception of serial binary data at high-speed (bit rate of 1.2K bits per second).
For the COMSWITCH-H, the operating bit rate is set at 1.2K bits per second for operation.
1.1.3 Security Features of the COMSWITCH-II
To preclude the possibility of unwarranted intrusion, the COMSWITCH-II provides security features to safeguard
the integrity of the host system. There are specific COMSWITCH-II functional commands that may only be
executed by the on-site user, as well as commands that are unique to the remote user. Some commands may be
executed by both the on-site and the remote user. There are three system access levels:
NONE
Remote port is unable to connect to the MV/7800 computer system and cannot
change any of the configuration data. The local operator can change password,
dialstring, and configuration data.
LIMITED
Remote port can connect to the MV/7800 computer IAC port or only
communicate with the user terminal, but cannot change any of the
configuration data. The local operator cannot change password, dialstring,
or configuration data.
FULL
Remote port can connect to both port/pairs of the MV/7800 computer, and
can change the configuration parameters. The local operator cannot change
the password, dialstring, or configuration data.
The primary COMSWITCH-II security features are the password and dialstring options available to the on-site
user.
PASSWORD - The on-site user can select one 40-character password to be stored in the non-volatile
RAM. The remote user must match this password in order to establish a modem port connection and
subsequent access to the host system.
TELEPHONE DIALSTRING - The on-site user can select the option of storing one 40-character
dialstring in the COMSWITCH-II non-volatile RAM memory (when required, or when using a
non-autodial modem. This feature can be disabled). The thalstring is the actual string sent to the
autodial modem to dial the telephone number that the caller left. When a dialstring is used, remote
sessions can be established only from an agreed-upon telephone number.