2.10.12 <BREAK>U - USER Mode
This command is used to connect the remote terminal to an RS422 IAC port of the MV17800 computer and can
only be issued from the remote terminal. This command gives user terminal capabilities to the remote operator,
but the local user terminal is forced into the Read-only mode. This command also does the following:
ENABLE local console (if DISABLED, Read-only, or Conversation)
Terminate SYSTEM mode (if in SYSTEM mode)
In response to the <BREAK>U command, the following message will be received at the remote terminal and the
user terminal (and on the System console if in SYSTEM mode):
Possible error messages:
2.10.13 <BREAK>V - Configuration VIEW/CHANGE
This command is used to view and change the parameters of the various serial I/O ports. This command allows
the remote operator to verify the configuration of the host system. Some of these parameters are stored in the
nonvolatile RAM with some of them being fixed. The only parameter to be configured using this command is the
Baud rate of the IAC/USER port. The remaining information is for help purposes only. The default Baud rate on
the IAC/USER is 9600.
The signal protocol for the SYS/CPU ports is RS232 with a HARD busy.
The <BREAIC>V command can be issued from the system console, and the remote terminal. Access level (set
using <BREAK>Q) will affect which terminals will be allowed to make parameter changes. The remote terminal is
in the FULL setting and the system console in the NONE setting.