INPUTS
PRODUCT REFERENCE GUIDE
95
Input 2 Connections Using Matrix 320 Power
Figure 67 - PNP Input 2 Using Matrix 320 Power
Figure 68 - NPN Input 2 Using Matrix 320 Power
CAUTION
Power from the Vdc/GND spring clamps is available directly to the Input
Device on the +V/-V spring clamps, and does not pass through the Power
Switch (ON/OFF) inside the CBX. Disconnect the power supply when
working inside the CBX.