STEP 7 - TEST MODE
PRODUCT REFERENCE GUIDE
29
STEP 7 - TEST MODE
Use a code suitable to your application to test the reading performance of the system.
1. Enter the Test function by pressing and holding the X-PRESS push button until the
Test LED is on.
2. Release the button to enter the Test function.
Once entered, the Bar Graph on the five LEDs is activated and if the reader starts
reading codes the Bar-Graph shows the Good Read Rate.
Figure 15 - X-PRESS Interface: Test Function
3. To exit the Test, press the X-PRESS push button once.
The Bar Graph has the following meaning:
In case of No Read condition, only the STATUS LED (red) is on and blinks.
NOTE
By default, the Test exits automatically after three minutes.