RAPID CONFIGURATION
2
MATRIX 320
CBX100/CBX500 Pinout for Matrix 320
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use
this pinout when the Matrix 320 reader is connected by means of the CBX100/CBX500:
* Do not leave floating, see "RS422 Full Duplex Interface" on page 84 for connection details.
GROUP LABEL DESCRIPTION
Input Power
Vdc Power Supply Input Voltage +
GND Power Supply Input Voltage -
Earth Protection Earth Ground
Inputs
+V Power Source - External Trigger
I1A External Trigger A (polarity insensitive)
I1B External Trigger B (polarity insensitive)
-V Power Reference - External Trigger
+V Power Source - Inputs
I2A Input 2 A (polarity insensitive)
I2B Input 2 B (polarity insensitive)
-V Power Reference - Inputs
Outputs
+V Power Source - Outputs
-V Power Reference - Outputs
O1+ Output 1 +
O1- Output 1 -
O2+ Output 2 +
O2- Output 2 -
O3A Output 3 - (CBX500 only)
Auxiliary
Interface
TX Auxiliary Interface TX
RX Auxiliary Interface RX
SGND Auxiliary Interface Reference
ID-NET™
REF Network Reference
ID+ ID-NET network data +
ID- ID-NET network data -
Main
Interface
RS232 RS422 Full Duplex
TX TX+
- TX-
RX *RX+
- *RX-
SGND SGND
CAUTION
Do not connect GND, SGND and REF to different (external) ground refer-
ences. GND, SGND and REF are internally connected through filtering
circuitry which can be permanently damaged if subjected to voltage
drops over 0.8 Vdc.