INTERNAL NETWORK CONFIGURATIONS
PRODUCT REFERENCE GUIDE
157
Verify Master/Slave Synchronized Configuration
From the Master configuration, run the application and monitor the output data from
the DL.CODE Console or a configured channel terminal.
If necessary, as a troubleshooting tip, you can temporarily apply the Reading Mask field
in place of each Code Content field to verify if all devices are reading. To do this:
1. Connect to the Master device via Ethernet and from the Data Formatting step,
change each Expected Code Field Type from Code Content to Reading Mask.
2. Run the application and monitor the output data from the DL.CODE Console or a
configured channel terminal.