5. User interface AUSTROMAT
®
664 iSiC
®
/ 674 baSiC
2
74 Operating Instructions (Version 03/2018)
5.8.2.3. Heating settings
In the "Setup" menu, click the [Heating settings] button. The following window is displayed for
setting customer-specific maximum levels for the start temperature [°C], power consumption [A]
and rise rate [°C/min].
Fig. 5-24 Setup > Heating settings
Buttons
• [OK]:
Accepts the settings and switches back to the "Setup" menu.
• [Maximum start temperature]:
Click on the button to activate and deactivate the "Maximum
start temperature" function. A green field within the button
indicates that the function is active
Maximum start
temperature
The maximum start temperature limits the start temperature of the
firing furnace. Change the maximum start temperature as follows:
• Click on the corresponding entry field. The numeric keyboard
window appears.
• Enter the desired value.
Maximum power
consumption
The maximum power consumption limits the power consumption of
the firing furnace. Change the maximum power consumption as
follows:
• Click on the corresponding entry field. The numeric keyboard
window appears.
• Enter the desired value.
Maximum rise rate The maximum rise rate limits the temperature ramp of the firing
furnace. Change the maximum rise rate as follows:
• Click on the corresponding entry field. The numeric keyboard
window appears.
• Enter the desired value.
U = … Displays the supply voltage level.