EasyManua.ls Logo

Dekema AUSTROMAT 674 baSiC - 7.3. Check Program for Diagnostics

Default Icon
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AUSTROMAT
®
664 iSiC
®
/ 674 baSiC
2
7. Maintenance and Service
Operating Instructions (Version 03/2018) 115
7.3. Check program
NOTE:
Start the check program only after running several firing programs, or after a cleaning
firing so that the firing oven is warmed up.
The AUSTROMAT
®
has an internal program, the check program, that checks the function of the
major components: the check program. Regularly running in this unchangeable program makes
it easier on you and the responsible service personnel
to identify old components such as heating element wear,
and eliminates malfunctions.
Start check program
After approximately 500 firings, the device will display a recommendation on the screen to start
the self-check program (this takes approximately 180 minutes depending on the set maximum
rise rate; see section 5.8.2.3).
In the "Setup" menu, sele
ct
the program "Check program", and press [Start] (see section
5.8.3.2).
Resul
t
s of the check program
The results of the self-check are saved in a diagnosis file (see section 5.8.4.3). If the diagnostic
data reveal that a firing pro
gram may not be able to be processed correctly, then the
AUSTROMAT
®
automatically points this out when a firing program is started. This is the case
for example when the heating element is too old, and you want to reach a firing temperature
quickly.
Error messages after running the check program
Error messages Measures
1. “NO ERRORS FOUND” No errors were found.
2. ‘CHANGE HEATING ELEMENT” Contact your service partner (see section
7.7).
Tab. 7-1 Overview of error messages
The error message "CHANGE HEATING ELEMENT" can also arise when the heating element
is technically functional. However, the check program requires a nominal power supply to
operate. When the power supply is below the nominal value, the error diagnosis of the heating
element can be incorrect. This problem generally only occurs in Asian countries. Consult your
local power company.