5 Applied Instructions and Basic Usage
DVP-20PM Application Manual
5-237
Descriptions of the parameters in the system used
Pulse type: A/B
Diameter of the master axis: 60 mm
Gear ratio for the mechanism used to decelerate the master axis:1:10
ar ration for the master axis: 128/4→128/4→ Ge The number of pulses it takes for the AC servo
akes for the AC servo drive
connected to the master axis to rotate once is 10,000. (Take Delta ASDA-A2 series AC servo
drive for instance.)
Length of a cutting: 1320 mm
Setting the parameters in the motion control function block T_FlyingSaw
MasterLength: 60 x π = 188→K188
MasterPulse: Number of pulses it takes for the master axis specified to rotate once/Gear ratio
for the mechanism used to decelerate the master axis specified→10000/0.1=100000→K100000
SlaveLength: K20
SlavePulse: K10000
SynArea: Approximately 1/3 times the distance for which the slave axis specified moves
forward→400/20x10000/3=66667→K66667
SflySwaLength: K400
ReturnRatio: K2
MaterialSize: K1320
AccCurve = K3 (Cycloid)
Operation of the cam used
Set the parameters in the motion control function block T_FlyingSaw. After M0 is set to ON, the
slave axis specified will mesh with the master axis specified.
After M10 is set to ON, the master axis will operate, and the motion of the slave axis will follow
the motion of the master axis.
Upload the cam chart in the DVP-20PM series motion controller used.
drive connected to the master axis to rotate once is 10,000.
(Take Delta ASDA-A2 series AC
servo drive for instance.)
Pitch: 20 mm
Distance for which the slave axis moves forward: 400 mm
Gear ratio for the slave axis: 128/4→The number of pulses it t