Part II: S
ettings and Measurements
72
PSI/SI Table Repetition Time
Service Information Max. interval
(complete table)
Min. interval
(single sections)
PAT 0.5s 25ms
CAT 0.5s 25ms
PMT 0.5s 25ms
NIT 10s 25ms
SDT 2s 25ms
BAT 10s 25ms
EIT 2s 25ms
RST - 25ms
TDT 30s 25ms
TOT 30s 25ms
TR 101 290 Priority 1, 2 and 3 Tests Event List
TR 101 290 Priority 1, 2 and 3 Tests Event List describes the detailed information for every event, including the
number, record time and error detailed information.
9-4 PID Viewer
Describes the information with section, simplified info, value(%), PID and the CR of every PID of the stream.
PID View
Section: The PID type, e.g., PSI/SI, video PID or Audio PID.
PID: The PID value.
CR: The bitrate of the PID.
The Value and CR are calculated in one-second increments.