Part II: Settings and Measurements
TR 101 290 Priority 1, 2 and 3 Parameter Limits
You can set measurement limits on TR 101 290 Priority 1, 2 and 3 tests, applying them to real-time TS analysis.
(See above.) Closing and re-opening the TS analysis mode will reset all limits back to default values.
PSI/SI Table Repetition Time
Serv
ice Information
Max. interval
(complete table)
Min. interval
(single sections)
PAT
0.5s
25ms
CAT
0.5s
25ms
PMT
0.5s
25ms
NIT
10s
25ms
SDT
2s
25ms
BAT
10s
25ms
EIT
2s
25ms
RST
-
25ms
TDT
30s
25ms
TOT
30s
25ms
Channel Parameters Setup Other Parameters Setup
You can select from two standards: DVB and ATSC.
Choose DVB to view PSI/SI analysis, and ATSC to view
PSI/PSIP analysis (shown, right).
DVB (PSI/SI: Program Specific Information/ Service
Information)
ATSC (PSI/PSIP: Program Specific Information /Program
and System Information Protocol)